Northern MeditecNorthern Meditec Crius V6 — blower-driven ICU ventilator
Blower-driven fully-electronic ICU ventilator — 15.6" SVGA touchscreen, full mode set (A/C-VCV, A/C-PCV, A/C-PRVC, SIMV variants, BIPAP, APRV, CPAP/PSV, CPAP-VG, NIV, IV), tidal volume 5–2000 mL, 2× 5200 mAh hot-swap batteries.
Configuration, accessories, lead time and service tier are quoted to your scope. Our specialists return a tailored offer within two business hours.
- Manufacturer warranty
- Worldwide delivery
- Installation & training
- Full documentation pack
Overview
The Crius V6 is Northern Meditec's blower-driven ICU ventilator — fully electronic control with a 15.6" SVGA active-matrix TFT touchscreen (1366×768). Patient range: adult, pediatric, neonate (height and weight adjustable). Tidal volume 5–2000 mL, PEEP/CPAP 0–50 cmH2O, FiO2 21–100 %, I:E 1:10 to 4:1, inspiratory time 0.2–5 s. Modes: A/C-VCV, A/C-PCV, A/C-PRVC, SIMV-VC, SIMV-PC, SIMV-PRVC, BIPAP, APRV, CPAP/PSV, CPAP-VG, NIV, IV. Special functions: manual breath, O2 therapy, standby, screen-lock, inspiratory / expiratory hold, sigh, ATC, PCVR, PPS, compliance, p0.1, calibrate, nebulizer, O2 suction. Real-time waveforms Paw / Flow / Volume / EtCO2 / SpO2 (optional). Loops P-V, V-Flow, Flow-P. Trends 1s / 5s / 1m / 10m / 30m / 60m. Two 5200 mAh hot-swappable lithium batteries. Oxygen supply 280–600 kPa (41–87 psi) at 120 L/min. Comprehensive alarm set with 1–9 loudness, 1000-event log. <45.3 kg, 600×402×415 mm.
Key features
- 15.6" SVGA active-matrix TFT touchscreen (1366×768)
- Patient range: adult, pediatric, neonate — height + weight adjustable
- Modes: A/C-VCV / PCV / PRVC, SIMV variants, BIPAP, APRV, CPAP/PSV, CPAP-VG, NIV, IV
- Tidal volume 5–2000 mL, PEEP/CPAP 0–50 cmH2O, FiO2 21–100 %
- Special functions: manual breath, O2 therapy, holds, sigh, ATC, PCVR, PPS, p0.1, nebulizer
- Waveforms: Paw, Flow, Volume, EtCO2, SpO2 (opt); Loops: P-V, V-Flow, Flow-P
- 2× 5200 mAh hot-swappable lithium batteries
- Oxygen supply 280–600 kPa @ 120 L/min
- Nurse call, USB, NET, RS232, VGA interfaces
- 1000-event log; alarm loudness 1–9
- <45.3 kg footprint, 600×402×415 mm
Clinical applications
Gallery

Specifications
- Display
- 15.6" SVGA active-matrix TFT touchscreen (1366×768)
- Patient range
- Adult / pediatric / neonatal
- Modes
- A/C-VCV, A/C-PCV, A/C-PRVC, SIMV-VC, SIMV-PC, SIMV-PRVC, BIPAP, APRV, CPAP/PSV, CPAP-VG, NIV, IV
- Tidal volume
- 5–2000 mL
- PEEP / CPAP
- 0–50 cmH2O
- FiO2
- 21–100 %
- I:E
- 1:10 to 4:1
- Battery
- 2× 5200 mAh hot-swap lithium
- Oxygen supply
- 280–600 kPa @ 120 L/min
- Connectivity
- Nurse call, USB, NET, RS232, VGA
- Weight / size
- <45.3 kg · 600×402×415 mm