United ImagingUnited Imaging uMR 670 — 1.5T 70 cm wide-bore MRI (48-channel)
1.5T wide-bore (70 cm) MRI with 48 independent receive channels, 24-ch spine coil, 18 kW RFPA, 33/57 mT/m gradient, 250 kg table SWL, zero helium boil-off and uAiFI deep-learning reconstruction.
Configuration, accessories, lead time and service tier are quoted to your scope. Our specialists return a tailored offer within two business hours.
- Manufacturer warranty
- Worldwide delivery
- Installation & training
- Full documentation pack
Overview
The uMR 670 is United Imaging's 1.5T wide-bore MRI — 70 cm patient bore, 0.831 ppm magnet homogeneity over 50 cm DSV, zero helium boil-off, active + passive shimming. The 48-channel RF receiver pairs with high-density coils (head/neck 16-ch, body array 12-ch, spine 24-ch, large/small flex 8-ch, knee 12-ch, shoulder 12-ch) routed through 8 coil ports on the patient table. Gradient: 33 mT/m peak (effective 57), 130 mT/m/ms slew rate (effective 225). 18 kW water-cooled RFPA with digital interface, tuning-free transmit coil, fully-digital quadrature demodulation. Compute: 3.9 GHz host CPU + 16-core 2.1 GHz reconstruction CPU = 100k images/sec at 256². Maximum FOV 500 mm, 2D slice thickness down to 0.1 mm, 3D down to 0.05 mm, b-value to 10000. uAiFI deep-learning reconstruction (Deep Recon), uCS compressed sensing, uSWIFT for abdominal SWI, MRS for brain / breast / liver / prostate. Easy Sense radar-based deviceless respiratory gating. Smart examination one-button push (Easy Plan head / spine / knee / whole-body).
Key features
- 70 cm patient bore — wide-bore design for patient access
- 48 independent receive channels, 8 coil ports on table
- 24-channel spine coil, 12-channel body / knee / shoulder coils
- Gradient: 33 mT/m peak (effective 57), 130 mT/m/ms slew (effective 225)
- 18 kW water-cooled RFPA with digital interface
- Tuning-free transmit coil, fully-digital quadrature demodulation
- Zero helium boil-off (0.0 L/year)
- Magnet homogeneity 0.831 ppm over 50 cm DSV
- uAiFI deep-learning reconstruction (Deep Recon)
- uCS compressed sensing for static + dynamic imaging
- uSWIFT abdominal SWI · MRS for brain / breast / liver / prostate
- Easy Sense deviceless respiratory gating (radar-based)
- Smart exam: One-button push Easy Plan for head / spine / knee / whole-body
- 250 kg table SWL · 205 cm scan range
- DICOM 3.0 + PACS + worklist · 5-year warranty on UIH items
Clinical applications
Gallery

Specifications
- Field strength
- 1.5T superconductor
- Bore
- 70 cm wide-bore
- Receive channels
- 48 independent · 8 coil ports on table
- Coil portfolio
- Head/neck 16-ch · body array 12-ch · spine 24-ch · large/small flex 8-ch · knee 12-ch · shoulder 12-ch
- Gradient
- 33 mT/m peak (effective 57) · 130 mT/m/ms slew (effective 225)
- Magnet stability
- 0.1 ppm/h · 0.831 ppm homogeneity over 50 cm DSV
- Helium boil-off
- 0.0 L/year — zero-boil-off
- RFPA
- 18 kW water-cooled with digital interface
- Max FOV / matrix
- 500×500×500 mm · acquisition 1024² · recon 2048²
- Slice thickness
- 2D min 0.1 mm · 3D min 0.05 mm
- Max b-value (DWI)
- 10000
- Reconstruction
- Deep Recon (uAiFI deep learning) + uCS Processing Engine · 100k img/s (256²)
- Advanced apps
- uCS · Deep Recon · uSWIFT · MRS (brain/breast/liver/prostate) · Easy Sense gating · One-button Easy Plan
- Table SWL
- 250 kg · 205 cm scan range
- Workstation
- uWS — Intel 4-core 3.6 GHz, 32 GB RAM, 24" 1920×1200; DICOM 3.0 / PACS
- Warranty
- 5 years on UIH items