United ImagingUnited Imaging uMammo 890i — dual-angle DBT with CMOS detector + uStereo biopsy
"Pushing the Boundary of Breast Imaging." Dual-angle DBT (40° wide-angle diagnostic + 15° narrow-angle screening) on a true CMOS detector (49.5 μm pixel, 10.1 lp/mm). uStereo ±1 mm biopsy, AI BI-RADS reporting, 30–40 % dose reduction.
Configuration, accessories, lead time and service tier are quoted to your scope. Our specialists return a tailored offer within two business hours.
- Manufacturer warranty
- Worldwide delivery
- Installation & training
- Full documentation pack
Overview
The uMammo 890i is United Imaging's flagship mammography platform — pushing digital breast tomosynthesis into a new image-quality / dose balance. The CMOS detector (49.5 μm pixel pitch, 10.1 lp/mm spatial resolution) uses on-pixel amplification to enhance SNR vs traditional a-Si detectors — amplifying signal but not noise. Two acquisition modes target different clinical questions: 40° wide-angle DBT captures 21 projections in a single scan with high in-depth resolution (best for diagnostic exams + dense breasts), and 15° narrow-angle screening mode cuts scan time 30–40 % for population screening, generating DBT images plus synthesized U-view 2D in 30 seconds. uDose full-panel AEC covers the entire glandular area for accurate per-density exposure — including breasts with implants, heterogeneously dense and extremely dense breasts. Clinical dose reduction: 40 % vs conventional FFDM, 30 % vs conventional DBT (AGD 0.62 mGy FFDM, 1.04 mGy DBT). uStereo biopsy uses Multiview parallax (±15°) for ±1 mm target accuracy, with both vertical and horizontal approaches. AI BI-RADS — 4-step report in 1 minute: gland-type analysis, lesion detection, size/shape/density measurement, BI-RADS report. GRACE reading workstation with customizable DBT slice thickness and dedicated mammography keypad. Automatic image cropping reduces storage + transmission 70 %.
Key features
- 40° wide-angle DBT (21 projections) — diagnostic exams + dense breasts
- 15° narrow-angle screening mode — 30 s to DBT + synthesized U-view 2D
- True CMOS detector — 49.5 μm pixel, 10.1 lp/mm, on-pixel amplification
- 30–40 % dose reduction vs conventional (AGD 0.62 FFDM / 1.04 DBT mGy)
- uStereo biopsy — Multiview parallax (±15°) for ±1 mm target accuracy
- uStereo: both vertical and horizontal approaches
- AI BI-RADS — 4-step report in 1 minute
- GRACE reading workstation — customizable DBT slice thickness
- Dedicated mammography keypad for review efficiency
- Automatic image cropping — 70 % storage / transmission reduction
- uDose full-panel AEC — entire glandular area, all breast densities
- Intelligent compression with adaptive design
- Comfort-oriented design: breathing light guide, MLO armrest, anxiety-reducing UX
Clinical applications
Gallery

Specifications
- Detector
- True CMOS — 49.5 μm pixel, 10.1 lp/mm, on-pixel amplification
- Tomosynthesis modes
- 40° wide-angle (21 projections) + 15° narrow-angle screening
- Screening cycle (15°)
- ~30 s to DBT + synthesized U-view 2D
- Dose reduction
- −40 % FFDM · −30 % DBT vs conventional · AGD 0.62 / 1.04 mGy clinical
- Biopsy
- uStereo Multiview ±1 mm target accuracy · vertical + horizontal
- AI assistance
- BI-RADS report in 1 min — gland-type / lesion detection / measurement
- AEC
- uDose full-panel AEC — entire glandular area
- Reading workstation
- GRACE — customizable DBT slice thickness + mammography keypad
- Storage
- Automatic image cropping — 70 % storage / transmission reduction